Internal Fire Doors You Can Count On

At JB Kind we take internal fire doors very seriously and spend a lot of time and effort to ensure that we supply one of the most comprehensive fire door ranges in the UK.

What are Fire Doors?

Fire doors play an important role in saving lives and building regulations specify where they need to be fitted in residential and commercial property settings.

Thankfully fire doors do not have to look functional or boring and the good news is that all of our internal door ranges offer an FD30 (fire door 30 minutes) option.  Plus, we have glazed fire doors available from stock and can make bespoke fire doors to our customers’ specifications.  

Understanding fire doors can become quite complicated and to help explain the subject further, we’ve created some easy to digest Key facts about fire doors.

Take a look below to see which fire door options are available by range. We’ve created two ‘At Glance Guide’ tables that show the options for both solid and glazed FD30 fire doors.  Identifying whether fire doors are available from stock or can be ordered through our Bespoke Options service.

At a glance guide – solid fd30 fire doors

Door Range Available From Stock Bespoke FD30
Oak Contemporary all designs all designs
Oak Classic all designs Not available
Oak Shaker all designs Not available
Oak Cottage all designs excluding Rustic Oak Thames Original
Cherwell
Walnut all designs all designs excluding Axis
Laminates all designs Not available
Urban Industrial Not available Not available
Painted Finish all designs all designs
White Contemporary all designs all designs excluding Savoy and Ripple
White Classic all designs Not available
White Shaker all designs excluding Axis Ripple, Aurora and Quartz Not available
White Moulded all designs Not available

At a glance guide – glazed fd30 fire doors

Door Range Available From Stock Bespoke FD30
Oak Contemporary Emral Oak
Blenheim
all designs excluding Bela
Oak Classic Not available Not available
Oak Shaker Fuji FD30 Not available
Oak Cottage Thames 1 Light FD30 Cherwell Glazed
Walnut Not available all designs excluding Axis Glazed
Laminates Not available Not available
Urban Industrial Not available Not available
Painted Finish Not available all designs
White Contemporary Dominion
all designs excluding Ripple and Phoenix
White Moulded Faro
Canterbury 2 Light
Not available
White Shaker Tobago Not available
White Classic Not available Not available

Building Regulations for Domestic Internal Fire doors

For those undertaking a new build or renovating a property, there is a possibility that you may require some fire doors in the house.

The architect involved with the project will be able to clarify if and where fire doors need to be fitted.  Domestic fire doors are required if an internal door leads into an integral garage or if a property has three or more storeys, including loft conversions.

For more detailed information download our fact sheet Fire Doors and Building Regulations and also refer to Building Regulations Approved Document B – Fire safety: Volume 1 – Dwelling Houses

Fully Accredited Fire doors: BS 476 pt22 or EN1634-1:2000

All of our fire doors are fully accredited and tested in accordance with either BS 476 pt22 or EN1634-1:2000.  In addition, many of our fire doors are certificated by Warringtonfire and are identified by ‘Certifire FD30 Fire door’ within their product description. JB Kind’s membership of the BWF Fire Door Alliance Scheme supports the promotion of third party certification.

Fire Test Assessment reports – it is essential that internal fire doors are fitted in accordance with their certification, so please call us on 01283 554197 should you require a copy of the relevant report(s).

Every year we support Fire Door Safety Week an important initiative which helps raise the importance of safely fitted fire doors in our public places.  Read our blog for more information.

Fire Door FAQs

Why do fire doors need intumescent seals and where are they fitted?

Intumescent seals are an essential part of a fire door assembly, expanding to fill the gap between the door edge and frame when subjected to extreme heat. The seals are usually fitted into a door frame but can also be grooved into the door edge. Care must be taken to ensure that the correct intumescent seals, i.e. those specified in the door’s Fire Test Assessment report, are fitted to ensure compliance and performance.

Yes, many fire doors can be fitted as a pair. The fire door must have been successfully tested as a pair for this to be possible – which will be confirmed in the Fire Test Assessment report, along with details of how to fit the door pair to ensure compliance and performance.

It is best practise for a glazed fire door to be supplied pre-fitted with fully accredited fire rated glass by an approved supplier / fabricator, to ensure compliance and performance.

JB Kind are a Certifire approved door modifier and can glaze fire doors to order, ensuring compliance and peace of mind.

Usually three fire rated hinges (sometimes four) are required to fit a fire door. The size, type and positioning of the fire door hinges are confirmed in the door’s Fire Test Assessment report.

Trimming a fire door is not advised and must be kept to an absolute minimum, so as not to void the door’s fire certification. If in doubt, please refer to the door’s Fire Test Assessment report.

Fire door pocket systems are very specialised assemblies, and it is vital you check the validity of your chosen system before purchasing to ensure it is suitable for use with wooden doors. JB Kind’s pocket door system is not fire rated.

Yes, frosted fire glass is available. It is usually etched or sandblasted to create a level of obscurity.

Yes, fitting the correct fire rated ironmongery (hinges, overhead door closers, latches, locks, handles) forms part of the fire door’s test accreditation.

Building regulations stipulate that fire doors are required in:
  • A 2 storey house which has a door leading from an integral garage into the house.
  • A house which has 3 or more storeys (including loft conversions) must have fire doors to every habitable room off the stairwell.

Do I need fire doors in my home?


Certifications & Memberships